Introduction
What you need
Step 1
Induction Charging Coil
- Use the charging station to remove the a small plastic plug from the end of the toothbrush by inserting the charging station into the end insert and twisting counter-clockwise by 90 degrees.
Use the charging station to remove the a small plastic plug from the end of the toothbrush by inserting the charging station into the end insert and twisting counter-clockwise by 90 degrees.
1024
Step 2
- Remove the end cap from the bottom of the toothbrush by prying it off with a spudger.
Remove the end cap from the bottom of the toothbrush by prying it off with a spudger.
Step 3
- Remove the top cap by using a spudger to pry the plastic ring off of the toothbrush frame.
Remove the top cap by using a spudger to pry the plastic ring off of the toothbrush frame.
Step 4
- Use a spudger to loosen the two plastic tabs next to the induction coil that secure the internal assembly to the frame.
- Push on the rotating head in order to pop the assembly out of the black plastic casing.
- You can also use a spudger to leverage the assembly out, but this may break the copper wire connected to the induction coil, so be careful.
Use a spudger to loosen the two plastic tabs next to the induction coil that secure the internal assembly to the frame.
Push on the rotating head in order to pop the assembly out of the black plastic casing.
You can also use a spudger to leverage the assembly out, but this may break the copper wire connected to the induction coil, so be careful.
Step 5
- Unwrap the ends of the wires from the white plastic pegs using a pair of tweezers.
- Each wire end is wrapped around the peg 3-4 times.
Unwrap the ends of the wires from the white plastic pegs using a pair of tweezers.
Each wire end is wrapped around the peg 3-4 times.
Step 6
- Melt the solder at the two pads on either side of the top of the motherboard. This will require a high heat soldering iron. Remove the wire from the solder pads using tweezers once the solder melts.
Melt the solder at the two pads on either side of the top of the motherboard. This will require a high heat soldering iron. Remove the wire from the solder pads using tweezers once the solder melts.
Step 7
- Remove the induction coil by pulling the plastic tabs out of their keepers.
- A spudger can be used to remove the plastic tabs from their keepers if neccessary.
Remove the induction coil by pulling the plastic tabs out of their keepers.
A spudger can be used to remove the plastic tabs from their keepers if neccessary.
To reassemble your device, follow these instructions in reverse order.
Cancel: I did not complete this guide.
2 other people completed this guide.
Author
with 5 other contributors
Rachel Surridge
Member since: 11/06/2017
292 Reputation
1 Guide authored
Badges:
10
+7 more badges
Team
IUPUI, Team S1-G1, Harley Fall 2017
Member of IUPUI, Team S1-G1, Harley Fall 2017
IUPUI-HARLEY-F17S1G1
3 Members
12 Guides authored
Geoffrey Sacré - May 26, 2021
Reply
bonjour, ou puis je trouver une nouvelle bobine d’induction ou puis je remplacer simplement le fil de cuivre
juste une précision pour sortir l’intérieur de la brosse du manche il faut appuyez sur les deux pattes plastique en bas près de la boucle d’induction
on voit une des pattes a l’étape 5