Introduction

What you need

Step 1

              Diopter Adjustment Dial               
  • Remove the four 4.6mm J000 Phillips screws from the sides and two 3.2mm J000 Phillips screws along the bottom.

Remove the four 4.6mm J000 Phillips screws from the sides and two 3.2mm J000 Phillips screws along the bottom.

1024

Step 2

  • Remove the two 3.2mm J000 Phillips screws located on the bottom edge of the viewfinder cover.
  • Carefully remove the viewfinder cover.
  • Remove the two 4.4mm J000 Phillips screws located near the top edge of the viewfinder.

Remove the two 3.2mm J000 Phillips screws located on the bottom edge of the viewfinder cover.

Carefully remove the viewfinder cover.

Remove the two 4.4mm J000 Phillips screws located near the top edge of the viewfinder.

Step 3

  • Slide the Wide Plastic Opening Tool upwards along the underside of the rear casing.
  • Be careful not to disconnect the filament connections. Reinserting them can be difficult.
  • Slowly lower the casing into the position shown.

Slide the Wide Plastic Opening Tool upwards along the underside of the rear casing.

Be careful not to disconnect the filament connections. Reinserting them can be difficult.

Slowly lower the casing into the position shown.

Step 4

  • Use the Screwdriver J000 Phillips Head to remove the screw located at the lower-left corner of the face of the viewfinder glass.
  • Carefully lift the L-shaped clicker underneath the previously removed screw.

Use the Screwdriver J000 Phillips Head to remove the screw located at the lower-left corner of the face of the viewfinder glass.

Carefully lift the L-shaped clicker underneath the previously removed screw.

Step 5

  • Slide the faulty diopter adjustment dial off the rod.
  • Replace the diopter dial with a 1-cm wheel.

Slide the faulty diopter adjustment dial off the rod.

Replace the diopter dial with a 1-cm wheel.

To reassemble your device, follow these instructions in reverse order.

Cancel: I did not complete this guide.

                                                                                      One other person completed this guide.                                             

Author

                                      with 3 other contributors 

                    Gabriel Gonzalez Jr                     

Member since: 02/14/2017

325 Reputation

                                      3 Guides authored                  



                       Badges:
                       10







                                                        +7 more badges                           

Team

                       USF Tampa, Team 1-3, Kass Spring 2017                        

                                                  Member of USF Tampa, Team 1-3, Kass Spring 2017 



                    USFT-KASS-S17S1G3                     


                                            4 Members                     


                                            6 Guides authored