Introduction

What you need

Step 1

              Lens Connection Assembly               
  • Remove the four 5.4 mm J000 screws from the front lens mount.

Remove the four 5.4 mm J000 screws from the front lens mount.

1024

Step 2

  • Use your hands or the thin plastic opening tool to remove the external housing ring as well as the smaller internal ring underneath.
  • Keep in mind that the red dot should be on the left side of the face. A small hole on the right side keeps the external ring centered on the lens release button. A similar hole on the left side keeps the internal ring centered underneath.
  • The three short depressed sections of the internal ring should be facing into the camera during reassembly.

Use your hands or the thin plastic opening tool to remove the external housing ring as well as the smaller internal ring underneath.

Keep in mind that the red dot should be on the left side of the face. A small hole on the right side keeps the external ring centered on the lens release button. A similar hole on the left side keeps the internal ring centered underneath.

The three short depressed sections of the internal ring should be facing into the camera during reassembly.

Step 3

  • Use the Thin Plastic Opening Tool to release the black connection ring.
  • Insert the tool underneath the right side of the black ring to improve leverage.
  • Let the ring fall forward to reveal its underside.
  • Take care not to disconnect the filament connections from the camera as they can be very difficult to reconnect.

Use the Thin Plastic Opening Tool to release the black connection ring.

Insert the tool underneath the right side of the black ring to improve leverage.

Let the ring fall forward to reveal its underside.

Take care not to disconnect the filament connections from the camera as they can be very difficult to reconnect.

Step 4

  • Remove the two 2.7mm J000 phillips screws from the mount ring which connect to the ribbon of filament connections.
  • There are many small golden-colored springs and rivets within the black ring connector. They will fall out if held upside down. When reassembling, they should be in contact with the gold plating of the filament connection.

Remove the two 2.7mm J000 phillips screws from the mount ring which connect to the ribbon of filament connections.

There are many small golden-colored springs and rivets within the black ring connector. They will fall out if held upside down. When reassembling, they should be in contact with the gold plating of the filament connection.

To reassemble your device, follow these instructions in reverse order.

Cancel: I did not complete this guide.

                                                                                      2 other people completed this guide.                                             

Author

                                      with 3 other contributors 

                    Gabriel Gonzalez Jr                     

Member since: 02/14/2017

325 Reputation

                                      3 Guides authored                  



                       Badges:
                       10







                                                        +7 more badges                           

Team

                       USF Tampa, Team 1-3, Kass Spring 2017                        

                                                  Member of USF Tampa, Team 1-3, Kass Spring 2017 



                    USFT-KASS-S17S1G3                     


                                            4 Members                     


                                            6 Guides authored