Difficulty
Easy
Steps
4
Time Required
6 minutes
Sections
1
- Lens Connection Assembly
- 4 steps
Flags
0
BackPanasonic Lumix DMC-G5
Full Screen
Options
History
Save to Favorites
Download PDF
Edit
Translate
Get Shareable Link
Embed This Guide
Notify Me of Changes
Stop Notifications
Introduction
What you need
Step 1
Lens Connection Assembly
- Remove the four 5.4 mm J000 screws from the front lens mount.
Remove the four 5.4 mm J000 screws from the front lens mount.
1024
Step 2
- Use your hands or the thin plastic opening tool to remove the external housing ring as well as the smaller internal ring underneath.
- Keep in mind that the red dot should be on the left side of the face. A small hole on the right side keeps the external ring centered on the lens release button. A similar hole on the left side keeps the internal ring centered underneath.
- The three short depressed sections of the internal ring should be facing into the camera during reassembly.
Use your hands or the thin plastic opening tool to remove the external housing ring as well as the smaller internal ring underneath.
Keep in mind that the red dot should be on the left side of the face. A small hole on the right side keeps the external ring centered on the lens release button. A similar hole on the left side keeps the internal ring centered underneath.
The three short depressed sections of the internal ring should be facing into the camera during reassembly.
Step 3
- Use the Thin Plastic Opening Tool to release the black connection ring.
- Insert the tool underneath the right side of the black ring to improve leverage.
- Let the ring fall forward to reveal its underside.
- Take care not to disconnect the filament connections from the camera as they can be very difficult to reconnect.
Use the Thin Plastic Opening Tool to release the black connection ring.
Insert the tool underneath the right side of the black ring to improve leverage.
Let the ring fall forward to reveal its underside.
Take care not to disconnect the filament connections from the camera as they can be very difficult to reconnect.
Step 4
- Remove the two 2.7mm J000 phillips screws from the mount ring which connect to the ribbon of filament connections.
- There are many small golden-colored springs and rivets within the black ring connector. They will fall out if held upside down. When reassembling, they should be in contact with the gold plating of the filament connection.
Remove the two 2.7mm J000 phillips screws from the mount ring which connect to the ribbon of filament connections.
There are many small golden-colored springs and rivets within the black ring connector. They will fall out if held upside down. When reassembling, they should be in contact with the gold plating of the filament connection.
To reassemble your device, follow these instructions in reverse order.
Cancel: I did not complete this guide.
2 other people completed this guide.