Difficulty
Difficult
Steps
9
Time Required
20 minutes - 1 hour
Sections
2
- Philips Sonicare 2 Series Disassembly
- 6 steps
- Circuit Board
- 3 steps
Flags
0
BackPhilips Sonicare 2 Series
Full Screen
Options
History
Save to Favorites
Download PDF
Edit
Translate
Get Shareable Link
Embed This Guide
Notify Me of Changes
Stop Notifications
Introduction
What you need
Step 1
Philips Sonicare 2 Series Disassembly
- Pull upwards to remove the brush head from the top of the device.
Pull upwards to remove the brush head from the top of the device.
1024
Step 2
- Remove the 12 mm T8 Torx screw from the bottom of the toothbrush. After removing the screw, pry off the base with a plastic opening tool.
Remove the 12 mm T8 Torx screw from the bottom of the toothbrush. After removing the screw, pry off the base with a plastic opening tool.
Step 3
- Remove the internal electronic mechanism from the housing by prying the red clips shown in the figure. This removes the charging port.
- Be very careful not to damage the charging port during this step. Otherwise you will have to solder this part back to the device as shown in the second figure.
Remove the internal electronic mechanism from the housing by prying the red clips shown in the figure. This removes the charging port.
Be very careful not to damage the charging port during this step. Otherwise you will have to solder this part back to the device as shown in the second figure.
Step 4
- Next you will be able to remove the internal electronic mechanism as shown in the figure.
Next you will be able to remove the internal electronic mechanism as shown in the figure.
Step 5
- Remove the white battery cover as shown in the figure.
Remove the white battery cover as shown in the figure.
Step 6
- Remove the white circuit board cover as shown. This cover will require you to pry off the piece from the groves .
Remove the white circuit board cover as shown. This cover will require you to pry off the piece from the groves .
Step 7
Circuit Board
- Pry away the battery using an opening tool from the battery housing. This will break the circuit and avoid electric shock.
Pry away the battery using an opening tool from the battery housing. This will break the circuit and avoid electric shock.
Step 8
- Desolder the circuit board from the motor as shown.
Desolder the circuit board from the motor as shown.
Step 9
- Desolder the circuit board from the housing as shown to remove the board
Desolder the circuit board from the housing as shown to remove the board
To reassemble your device, follow these instructions in reverse order.
Cancel: I did not complete this guide.
One other person completed this guide.
Author
with 3 other contributors
Jonathan Jarvis
Member since: 04/01/2016
470 Reputation
4 Guides authored
Badges:
9
+6 more badges
Team
IUPUI, Team S6-G2, Baechle Fall 2017
Member of IUPUI, Team S6-G2, Baechle Fall 2017
IUPUI-BAECHLE-F17S6G2
3 Members
8 Guides authored