Difficulty

Difficult

Steps

9

Time Required

                          20 minutes - 1 hour            

Sections

2

  • Philips Sonicare 2 Series Disassembly
  • 6 steps
  • Motor
  • 3 steps

Flags

3

Action Shots

Be an action hero! This guide needs images that better demonstrate how to perform specific actions.

Needs Better Images

Better photos will improve this guide. Help out by taking, editing, or uploading new ones!

Missed a Step

Oops! This guide is currently missing some important steps.

  • BackPhilips Sonicare 2 Series

  • Full Screen

  • Options

  • History

  • Save to Favorites

  • Download PDF

  • Edit

  • Translate

  • Get Shareable Link

  • Embed This Guide

  • Notify Me of Changes

  • Stop Notifications

Introduction

What you need

Step 1

              Philips Sonicare 2 Series Disassembly               
  • Pull upwards to remove the brush head from the top of the device.

Pull upwards to remove the brush head from the top of the device.

1024

Step 2

  • Remove the 12 mm T8 Torx screw from the bottom of the toothbrush. After removing the screw, pry off the base with a plastic opening tool.

Remove the 12 mm T8 Torx screw from the bottom of the toothbrush. After removing the screw, pry off the base with a plastic opening tool.

Step 3

  • Remove the internal electronic mechanism from the housing by prying the red clips shown in the figure. This removes the charging port.
  • Be very careful not to damage the charging port during this step. Otherwise you will have to solder this part back to the device as shown in the second figure.

Remove the internal electronic mechanism from the housing by prying the red clips shown in the figure. This removes the charging port.

Be very careful not to damage the charging port during this step. Otherwise you will have to solder this part back to the device as shown in the second figure.

Step 4

  • Next you will be able to remove the internal electronic mechanism as shown in the figure.

Next you will be able to remove the internal electronic mechanism as shown in the figure.

Step 5

  • Remove the white battery cover as shown in the figure.

Remove the white battery cover as shown in the figure.

Step 6

  • Remove the white circuit board cover as shown. This cover will require you to pry off the piece from the groves .

Remove the white circuit board cover as shown. This cover will require you to pry off the piece from the groves .

Step 7

              Motor               
  • Disassemble the device. Remove the plastic piece over the brush attachment as shown. Object can be removed by hand as shown. No tool is required.

Disassemble the device. Remove the plastic piece over the brush attachment as shown. Object can be removed by hand as shown. No tool is required.

Step 8

  • Desolder the motor from the circuit board at the two locations shown.

Desolder the motor from the circuit board at the two locations shown.

Step 9

  • Remove the bad motor.

Remove the bad motor.

Cancel: I did not complete this guide.

Author

                                      with 4 other contributors 

                    Jonathan Jarvis                     

Member since: 04/01/2016

470 Reputation

                                      4 Guides authored                  



                       Badges:
                       9







                                                        +6 more badges                           

Team

                       IUPUI, Team S6-G2, Baechle Fall 2017                        

                                                  Member of IUPUI, Team S6-G2, Baechle Fall 2017 



                    IUPUI-BAECHLE-F17S6G2                     


                                            3 Members                     


                                            8 Guides authored