Difficulty

Moderate

Steps

11

Time Required

                          30 minutes - 1 hour            

Sections

1

  • Battery
  • 11 steps

Flags

Member-Contributed Guide

An awesome member of our community made this guide. It is not managed by iFixit staff.

  • BackPhilips Sonicare DiamondClean HX9340

  • Full Screen

  • Options

  • History

  • Save to Favorites

  • Download PDF

  • Edit

  • Translate

  • Get Shareable Link

  • Embed This Guide

  • Notify Me of Changes

  • Stop Notifications

Introduction

What you need

Step 1

              Battery               
  • Here is the Philips Sonicare handle HX9340 that no longer holds a charge
  • This is the bottom endcap that requires removal.
  • A few layers of cardboard gets wrapped around the handle to protect it from any marring or other damage.

Here is the Philips Sonicare handle HX9340 that no longer holds a charge

This is the bottom endcap that requires removal.

A few layers of cardboard gets wrapped around the handle to protect it from any marring or other damage.

1024

Step 2

  • BEFORE trying with tools, it is possible to get the cap off as well as the inner part of the toothbrush without any tools. This will not damage the toothbrush; actually it will possibly save the toothbrush from being marred.
  • Simply push the metal head at the top of the tootbrush downwards into a hard surface with some force and the bottom cap and the inner part will pop out by itself.
  • This works on both old and new Sonicare models.
  • If this worked for you, simply skip Steps 3–6.

BEFORE trying with tools, it is possible to get the cap off as well as the inner part of the toothbrush without any tools. This will not damage the toothbrush; actually it will possibly save the toothbrush from being marred.

Simply push the metal head at the top of the tootbrush downwards into a hard surface with some force and the bottom cap and the inner part will pop out by itself.

This works on both old and new Sonicare models.

If this worked for you, simply skip Steps 3–6.

Step 3

  • Using a pair of pliers to apply some pressure round the handle. The best place to start is the wider part of the rectangular base and about 1/2" to 3/4" from the bottom
  • Continue to apply pressures around the whole base of the the handle moving to each side of the rectangular base.
  • It may take a few complete rotations to finally open up the gap between base and handle.

Using a pair of pliers to apply some pressure round the handle. The best place to start is the wider part of the rectangular base and about 1/2" to 3/4" from the bottom

Continue to apply pressures around the whole base of the the handle moving to each side of the rectangular base.

It may take a few complete rotations to finally open up the gap between base and handle.

Step 4

  • Once the gap opens up, utilize a small flathead screwdriver to insert it into the gap to widen it.
  • Endcap coming out of the handle. Once the gasket will become completely visible
  • the endcap can be removed.

Once the gap opens up, utilize a small flathead screwdriver to insert it into the gap to widen it.

Endcap coming out of the handle. Once the gasket will become completely visible

the endcap can be removed.

Step 5

  • Here is the endcap showing the tabs that hold it securely in place once inserted
  • There will be two plastic tabs that hold the inner workings to the outside handle. These are hard to reach and not easy to see.
  • Using a long small flathead screwdriver (or similar tool) to find those tabs is the difficult part on this job.

Here is the endcap showing the tabs that hold it securely in place once inserted

There will be two plastic tabs that hold the inner workings to the outside handle. These are hard to reach and not easy to see.

Using a long small flathead screwdriver (or similar tool) to find those tabs is the difficult part on this job.

Step 6

  • Once the tabs have been properly located, insert one tool on each side to loosen compress the base and apply downward pressure on the outer handle. For this the top end of the handle needs to rest against a solid base. It does require a considerable amount of downward force to accomplish this.
  • With the tabs loosened and the handle opushed downward, the inner workings of the toothbrush will loosen and pop out of the handle.
  • Remove the mechanics out of the handle.

Once the tabs have been properly located, insert one tool on each side to loosen compress the base and apply downward pressure on the outer handle. For this the top end of the handle needs to rest against a solid base. It does require a considerable amount of downward force to accomplish this.

With the tabs loosened and the handle opushed downward, the inner workings of the toothbrush will loosen and pop out of the handle.

Remove the mechanics out of the handle.

Step 7

  • Remove the rubber protectors from the PCB side
  • as well as the battery.
  • Here is the battery to be replaced. Sanyo part number 4235 010 13068

Remove the rubber protectors from the PCB side

as well as the battery.

Here is the battery to be replaced. Sanyo part number 4235 010 13068

Step 8

  • There are three places that will have to be desoldered.
  • Positive battery contact
  • Negative battery contact
  • and a jumper
  • For the jumper the only thing required is to remove the solder between the pads.
  • Apply some flux to the jumper. The pliers will help to stabilize the PCB during soldering. any other means to hold it steady can be used.

There are three places that will have to be desoldered.

Positive battery contact

Negative battery contact

and a jumper

For the jumper the only thing required is to remove the solder between the pads.

Apply some flux to the jumper. The pliers will help to stabilize the PCB during soldering. any other means to hold it steady can be used.

Step 9

  • Using a soldering iron, remove the solder bridge between the jumper pads.
  • Using flux and desoldering braid remove the solder from the negative tab of the battery.
  • Solder bridge from jumper cleaned
  • Negative battery tab unsoldered from PCB

Using a soldering iron, remove the solder bridge between the jumper pads.

Using flux and desoldering braid remove the solder from the negative tab of the battery.

Solder bridge from jumper cleaned

Negative battery tab unsoldered from PCB

Step 10

  • Apply flux to the positive contact of the battery on the PCB (Incidental finding is a SMD fuse F1 on this PCB)
  • Using desoldering braid unsolder the positive contact from the PCB.
  • Apply some gentle pressure with a small tool to remove the battery.
  • The battery should remove easily. If it does not, double check the battery contacts on the PCB to ensure they are not still connected somewhere. Another going over with the soldering iron may be required to complete that task.

Apply flux to the positive contact of the battery on the PCB (Incidental finding is a SMD fuse F1 on this PCB)

Using desoldering braid unsolder the positive contact from the PCB.

Apply some gentle pressure with a small tool to remove the battery.

The battery should remove easily. If it does not, double check the battery contacts on the PCB to ensure they are not still connected somewhere. Another going over with the soldering iron may be required to complete that task.

Step 11

  • Battery removed from the PCB and the solder pads on the PCB are now clearly visible
  • In an attempt to determine the type off battery the red plastic covering was removed. The battery is a 3.7V lithium-ion battery that measures approximately (rounded) 14mmX49mm. Roughly the size of a AA battery.
  • The groove on the battery is always on the positive end of the battery.

Battery removed from the PCB and the solder pads on the PCB are now clearly visible

In an attempt to determine the type off battery the red plastic covering was removed. The battery is a 3.7V lithium-ion battery that measures approximately (rounded) 14mmX49mm. Roughly the size of a AA battery.

The groove on the battery is always on the positive end of the battery.

To reassemble your device, follow these instructions in reverse order.

Cancel: I did not complete this guide.

                                                                                      47 other people completed this guide.                                             

Author

                                      with 4 other contributors 

                    oldturkey03                     

Member since: 09/29/2010

722,341 Reputation

                                      109 Guides authored                  



                       Badges:
                       53







                                                        +50 more badges                           

Team

                       Global Fixers                        

                                                  Member of Global Fixers 



                    Community                     


                                            22 Members                     


                                            240 Guides authored                     

moritz - Jan 11, 2017

Reply

This has helped me a lot and i used it as a base for my fixit tutorial. Thank you!

Claes - Feb 12, 2017

Hallo moritz, bitte tausche in deiner Anleitung die Sprache in Englisch da jetzt die Deutsche Anleitung in Englisch geschrieben ist.

matze - Apr 23, 2017

Reply

Nach dem wechsel der Batterie leuchten alle Lampen, aber die Bürste gibt keine Vibrationen ab. Wo ist der fehler? Hatte jemand dieses Problem?

After replacement of the akku all lamps are flashing but there is no function of the vibration-module. anyone knows this problem?

Kilian Müller - Jun 8, 2020

Das wird wahrscheinlich daran liegen, dass zwischen der Antriebseinheit und der BürstenWelle kein Platz ist. Sprich der Magnet liegt auf der Antriebseinheit an. Um das Problem zu lösen musst du zwei feststellschrauben lösen, den Spalt herstellen und dann die feststellschrauben wieder anziehen. Dann sollte die BürstenAufnahme wieder schwingen.

Stephan Müller - Nov 14, 2017

Reply

Thanks for information. This guide leads to success. Thumbs up My Sonicare is back at work now. :-)