Difficulty
Moderate
Steps
7
Time Required
2 hours
Sections
1
- Solenoid valve coil
- 7 steps
Flags
Member-Contributed Guide
An awesome member of our community made this guide. It is not managed by iFixit staff.
BackРемонт Philips Dampfbügelstation GC9642/60
Full Screen
Options
History
Save to Favorites
Download PDF
Translate
Get Shareable Link
Embed This Guide
Notify Me of Changes
Stop Notifications
Introduction
What you need
Step 1
Preparation
- Pull out the plug. If necessary, allow the device to cool down for 10 minutes. Remove the water tank. Place the iron on a suitable surface.
Pull out the plug. If necessary, allow the device to cool down for 10 minutes. Remove the water tank. Place the iron on a suitable surface.
1024
Step 2
Empty the steam boiler
- Place a suitable container to catch the water.
- Unscrew the stopper plug counterclockwise and set it aside.
Place a suitable container to catch the water.
Unscrew the stopper plug counterclockwise and set it aside.
Step 3
Remove the bottom of the device
- Turn the device upside down.
- Use a long screwdriver to remove 6 Torx # 15 screws
- Remove 2 screws with a Philips # 1 screwdriver
Turn the device upside down.
Use a long screwdriver to remove 6 Torx # 15 screws
Remove 2 screws with a Philips # 1 screwdriver
Step 4
Open device
- Place the unit with the bottom facing downwards. Carefully lift the upper part.
- The keyboard in the upper part is connected by a cable harness to the motherboard. Grab the corresponding plug on both sides and remove them carefully.
- Remove the clear hose between the water tank and the pump on the pump side. To do this, grasp under the lower edge of the hose and pull up with bending or rotating movements.
- The upper part can now be put aside.
Place the unit with the bottom facing downwards. Carefully lift the upper part.
The keyboard in the upper part is connected by a cable harness to the motherboard. Grab the corresponding plug on both sides and remove them carefully.
Remove the clear hose between the water tank and the pump on the pump side. To do this, grasp under the lower edge of the hose and pull up with bending or rotating movements.
The upper part can now be put aside.
Step 5
Measuring the solenoid valve coils resistance
Remove the rubber protection cap from the cable lug of the conductor.
Disconnect both cables from the spool. To do this, use a pointed object (eg a small screwdriver) to push the lock of the cable lug outwards, and at the same time pulling the cable lug away from the valve.
Use a multimeter to measure the resistance between the two contacts. It should (at least briefly) be at 30 ohms. If the resistance is infinite, the coil is defective and needs to be replaced.
Step 6
Removing the solenoid coil
- In order to disassemble the coil the valve must be turned approximately 30° counterclockwise. Replacing the whole valve doesn’t make a lot of sense here, because the pressure hoses are partly glued together or are fixed in place with clamping rings.
- Remove 2 Phillips screws #1 to give the hose connected to the iron more play.
- Pull off the cable lug of the heat sensor, while pushing the pawl outwards.
- Grab the whole valve and turn it counterclockwise until the coil is able to squeeze past the black pressure hose. You may need pliers.
- Open the fixing nut turning a wrench counterclockwise and pull off the coil.
In order to disassemble the coil the valve must be turned approximately 30° counterclockwise. Replacing the whole valve doesn’t make a lot of sense here, because the pressure hoses are partly glued together or are fixed in place with clamping rings.
Remove 2 Phillips screws #1 to give the hose connected to the iron more play.
Pull off the cable lug of the heat sensor, while pushing the pawl outwards.
Grab the whole valve and turn it counterclockwise until the coil is able to squeeze past the black pressure hose. You may need pliers.
Open the fixing nut turning a wrench counterclockwise and pull off the coil.
Step 7
Assembly
- Assembly is done by following the steps in reverse order.
Assembly is done by following the steps in reverse order.
To reassemble your device, follow these instructions in reverse order.
Cancel: I did not complete this guide.
15 other people completed this guide.
These translators are helping us fix the world! Want to contribute? Start translating ›
Special thanks to these translators:
100%
eliaskrenn
Annika Faelker
BenZ78
Андрей Медзавишвили
and 1 other…
+1
Author
with 1 other contributor
John Maier
Member since: 08/29/2017
1,207 Reputation
3 Guides authored
Badges:
15
+12 more badges
Kemal Zafer - Jan 4, 2019
Reply
Vielen Dank für die tolle Einleitung! Leider sind wir von diesem Problem auch betroffen. Wollte kurz fragen ob Sie die Magnetventilspule irgendwo noch gefunden haben?
Kann man eventuell dieses nutzen? Das Modell 9640 ist nicht unter “Geeignet Für“ aufgelistet, aber ich denke nicht dass die für jedes Modell ein anderes Ventil nutzen.
https://www.fiyo.de/philips-ventil-quadr…
John Maier - Jan 6, 2019
Hallo,
Unter Schritt 5 habe ich einen Link angegeben, wo ich das Ventil bekommen habe. Es ist von Jiayin, mit “JYZ-5” beschriftet und hat eine Leistung von 17 Watt.
Unter Ihrem Link findet sich ein “JYZ-4P” von Jiayin mit 12 Watt Leistung.
Optisch scheinen sie baugleich, ob der Leistungsunterschied relevant ist kann ich leider nicht sagen.
Bitte rückmelden, falls es funktioniert hat. Der Preisunterschied ist deutlich.
Tolga - Sep 15, 2022
Kann es trotzdem an der Spule liegen auch wenn ich dir spule schalten höre wenn ich die Taste am Bügeleisen bettätige ??
Maxim - Jul 17, 2019
Reply
besten Dank für diese Anleitung. Mein Philips GC9622 hatte ebenfalls eine defekte Magnetventilspule. Knapp 3 Jahre nach dem Kauf. Nach dem Austausch der Spule kommt wieder Dampf. Mal sehen wie lange diese Spule hält.
Ich habe hier https://www.ersatzteileshop.de/ventil-42… das original Ersatzteil für knapp 25€ gefunden (31€ mit Versand).
Besten Dank und Viele Grüße
Maxim
John Maier - Nov 12, 2019
Danke für die Rückmeldung.
John