Difficulty
Easy
Steps
4
Time Required
10 minutes
Sections
2
- Top cover
- 2 steps
- Power Board
- 2 steps
Flags
1
Member-Contributed Guide
An awesome member of our community made this guide. It is not managed by iFixit staff.
BackRoland G-800
Full Screen
Options
History
Save to Favorites
Download PDF
Edit
Translate
Get Shareable Link
Embed This Guide
Notify Me of Changes
Stop Notifications
What you need
Step 1
Top cover
- Turn the keyboard upside down to access the screws
- Remove 15 Philips PH2 screws
- Don’t worry about the other 16 screws, they hold the keys to the bottom case.
Turn the keyboard upside down to access the screws
Remove 15 Philips PH2 screws
Don’t worry about the other 16 screws, they hold the keys to the bottom case.
1024
Step 2
- Turn the keyboard upright again and lift the top cover from the front
- Remove 6 connectors
Turn the keyboard upright again and lift the top cover from the front
Remove 6 connectors
Step 3
Power Board
- Remove the power output connector
- Take note of the order of the wires here. In this case we have the white (neutral) wire on the left, but always double check when working with mains wiring.
- Loosen the two flathead screws holding the mains wires to release them
Remove the power output connector
Take note of the order of the wires here. In this case we have the white (neutral) wire on the left, but always double check when working with mains wiring.
Loosen the two flathead screws holding the mains wires to release them
Step 4
- Remove 4 PH2 screws holding the board to the case.
Remove 4 PH2 screws holding the board to the case.
To reassemble your device, follow these instructions in reverse order.
Cancel: I did not complete this guide.
4 other people completed this guide.
Author
with 2 other contributors
Andrew
Member since: 05/08/2010
1,311 Reputation
5 Guides authored
Badges:
13
+10 more badges