Introduction

The magnet tray located near the bottom of the Ryobi P235 impact driver can be used to hold screws, nails, and other magnet accessories during impact driving use.

Overtime the magnet tray can become damaged, faulty, or overall unusable. In this guide you will learn how to easily and effectively swap it out!

This replacement isn’t very challenging, but in any repair or replacement be careful and use proper safety equipment. It is recommended to wear eye protection incase of any flying repair parts. It is also recommended to wear gloves just in case one of the metal edges is charp. It is important to note that before the replacement remove the battery from the impact driver.

No special skills are needed in this repair! So have fun and enjoy your new magnet tray!

What you need

Step 1

              Battery               
  • Push in both push tabs on the battery at the same time.
  • They are located below the green housing and are in the middle on both sides of the battery.

Push in both push tabs on the battery at the same time.

They are located below the green housing and are in the middle on both sides of the battery.

1024

Step 2

  • Pull the battery away from the drill housing while holding in both tabs.

Pull the battery away from the drill housing while holding in both tabs.

Step 3

              Magnetic Tray               
  • Use a Phillips #2 screwdriver to remove the eight 16 mm screws that secure the housing.

Use a Phillips #2 screwdriver to remove the eight 16 mm screws that secure the housing.

Step 4

  • Use a T20 Torx screwdriver to remove the four 25.4 mm screws that secure the front of the housing.

Use a T20 Torx screwdriver to remove the four 25.4 mm screws that secure the front of the housing.

Step 5

  • Open the housing with the data label facing up.

Open the housing with the data label facing up.

Step 6

  • Remove the magnetic tray from the device.

Remove the magnetic tray from the device.

To reassemble your device, follow these instructions in reverse order.

Cancel: I did not complete this guide.

Author

                                      with 5 other contributors 

                    Paul Sousa                     

Member since: 10/29/2019

748 Reputation

                                      5 Guides authored                  



                       Badges:
                       9







                                                        +6 more badges                           

Team

                       UMass Dartmouth, Team S4-G2, Saloman Fall 2019                        

                                                  Member of UMass Dartmouth, Team S4-G2, Saloman Fall 2019 



                    UMASSD-SALOMAN-F19S4G2                     


                                            3 Members                     


                                            6 Guides authored                     

Mark Robert - Dec 23, 2019

Reply

Thanks for sharing, I was actually looking for these steps.