Introduction
What you need
Step 1
Blade
- Locate the area where the blade is connected to the motor, where the circular covering is on the Ryobi P501G.
Locate the area where the blade is connected to the motor, where the circular covering is on the Ryobi P501G.
1024
Step 2
- Unscrew clockwise and remove the bearing in the middle, connecting the blade to the motor. This will also allow removal of the blade guard.
Unscrew clockwise and remove the bearing in the middle, connecting the blade to the motor. This will also allow removal of the blade guard.
Step 3
- Remove the four black screws holding the black bearing and remove the bearing itself.
Remove the four black screws holding the black bearing and remove the bearing itself.
Step 4
- Once the black bearing is off, remove the transparent cover of the blade.
- Once the cover is off, remove the blade.
- Place the new blade with the flat notches lined up with the flat notches on the motor axle.
Once the black bearing is off, remove the transparent cover of the blade.
Once the cover is off, remove the blade.
Place the new blade with the flat notches lined up with the flat notches on the motor axle.
Step 5
Shell
- Remove the three screws on the inside base of the metal casing of the blade.
- Pull the metal blade casing off of the Ryobi P501G body.
Remove the three screws on the inside base of the metal casing of the blade.
Pull the metal blade casing off of the Ryobi P501G body.
Step 6
- Remove all of the screws located on the right side of the saw.
- Separate the right side of the saw from the left side by pulling away once all of the screws are removed.
- Pull back the shell to access the housed parts underneath.
Remove all of the screws located on the right side of the saw.
Separate the right side of the saw from the left side by pulling away once all of the screws are removed.
Pull back the shell to access the housed parts underneath.
To reassemble your device, follow these instructions in reverse order.
Cancel: I did not complete this guide.
Author
with 2 other contributors
Eeshan Mishra
Member since: 01/24/2019
412 Reputation
4 Guides authored
Badges:
7
+4 more badges
Team
Cal Poly, Team S1-G2, Maness Spring 2019
Member of Cal Poly, Team S1-G2, Maness Spring 2019
CPSU-MANESS-S19S1G2
4 Members
7 Guides authored