- Remove Siemens EQ Series side panel (tank side).
- 6 steps
- ceramic valve
- 7 steps
- Revise ceramic valve
- 2 steps
Flags
1
Member-Contributed Guide
An awesome member of our community made this guide. It is not managed by iFixit staff.
BackSiemens EQ Series
Full Screen
Options
History
Save to Favorites
Download PDF
Translate
Get Shareable Link
Embed This Guide
Notify Me of Changes
Stop Notifications
What you need
Step 1
Remove Siemens EQ Series side panel (tank side).
- Never forget: pull out the mains plug!
- Remove all attachments such as water tank, pulp drawer, brew group.
- Remove the coffee container lid and take out all the coffee beans.
Never forget: pull out the mains plug!
Remove all attachments such as water tank, pulp drawer, brew group.
Remove the coffee container lid and take out all the coffee beans.
1024
Step 2
- Unscrew the two Torx T10 screws at the top of the right side panel.
- Some models do not have these screws. Then the side parts are only held by catches, some of which clamp very strongly. You may have to detach the back part first.
Unscrew the two Torx T10 screws at the top of the right side panel.
Some models do not have these screws. Then the side parts are only held by catches, some of which clamp very strongly. You may have to detach the back part first.
Step 3
- Lay the machine on its side with the water tank side facing up.
- The side panel is essentially held on the ground by five strong catches. Pry up the pegs with a strong prying tool. It’s pretty difficult and you need a lot of strength.
- If the catches are loose, you can pull the side panel away from below. But it’s still stuck in other places.
- Use a plastic tool to pry the top cover up a few millimeters and lift off the side panel. Most of the time it’s still stuck, especially at the front edge, you have to pull hard.
Lay the machine on its side with the water tank side facing up.
The side panel is essentially held on the ground by five strong catches. Pry up the pegs with a strong prying tool. It’s pretty difficult and you need a lot of strength.
If the catches are loose, you can pull the side panel away from below. But it’s still stuck in other places.
Use a plastic tool to pry the top cover up a few millimeters and lift off the side panel. Most of the time it’s still stuck, especially at the front edge, you have to pull hard.
Step 4
- You may need to pry the front edge with a plastic tool.
- Lift the side panel off, but don’t remove it completely yet. It is still connected with a silicone tube.
- The water tank lid is located at the top of the side panel. Lift it up off the hinges.
You may need to pry the front edge with a plastic tool.
Lift the side panel off, but don’t remove it completely yet. It is still connected with a silicone tube.
The water tank lid is located at the top of the side panel. Lift it up off the hinges.
Step 5
- Pull off the silicone hose that leads to the water connection of the tank from the inside.
Pull off the silicone hose that leads to the water connection of the tank from the inside.
Step 6
- Remove the cover over the electronics.
- The second picture shows the most important components:
- heater
- ceramic valve
- electronics
- pump
- mute
- flow meter
Remove the cover over the electronics.
The second picture shows the most important components:
heater
ceramic valve
electronics
pump
mute
flow meter
Step 7
ceramic valve
- If you haven’t already done so: Remove the two plastic covers over the cables and the electronics box.
If you haven’t already done so: Remove the two plastic covers over the cables and the electronics box.
Step 8
- Locate the two strands of wire going from the ceramic valve to the motherboard. Unplug the connectors and unthread the cables.
Locate the two strands of wire going from the ceramic valve to the motherboard. Unplug the connectors and unthread the cables.
Step 9
- Turn the machine over. Remove the three Torx T15 screws securing the ceramic valve. Pay attention to the washers.
Turn the machine over. Remove the three Torx T15 screws securing the ceramic valve. Pay attention to the washers.
Step 10
- Turn the machine over again.
- Pull out the clamp on the pressure hose to the ceramic valve.
- Pull off the pressure hose and push it aside.
Turn the machine over again.
Pull out the clamp on the pressure hose to the ceramic valve.
Pull off the pressure hose and push it aside.
Step 11
- Carefully pull out the valve.
- Pull off the thick and thin silicone hoses.
Carefully pull out the valve.
Pull off the thick and thin silicone hoses.
Step 12
- Pull off the clamps on the other two pressure hoses. Make a note of which hose goes where and detach the two hoses.
Pull off the clamps on the other two pressure hoses. Make a note of which hose goes where and detach the two hoses.
Step 13
- Remove the ceramic valve.
Remove the ceramic valve.
Step 14
Revise ceramic valve
- Unscrew the four Torx T20 screws holding the ceramic valve together.
Unscrew the four Torx T20 screws holding the ceramic valve together.
Step 15
- Carefully disassemble the valve into two parts.
- Take out the ceramic discs very carefully. If they fall, they may break!
- Slide the slices apart. Clean and descale them.
- The discs can only be reinstalled in one way. Pay attention to the narrow and wide grooves. The smooth sides must face the larger and moveable middle disk.
- Carefully detach and clean the two black rubber seals. Note how they are installed.
- Blow into all canals and check that they are clear.
- If the valve does not find a position, one or both microswitches are defective. Then you have to exchange them. These are easily available standard types from SAIA, the type designation is printed on them.
Carefully disassemble the valve into two parts.
Take out the ceramic discs very carefully. If they fall, they may break!
Slide the slices apart. Clean and descale them.
The discs can only be reinstalled in one way. Pay attention to the narrow and wide grooves. The smooth sides must face the larger and moveable middle disk.
Carefully detach and clean the two black rubber seals. Note how they are installed.
Blow into all canals and check that they are clear.
If the valve does not find a position, one or both microswitches are defective. Then you have to exchange them. These are easily available standard types from SAIA, the type designation is printed on them.
Follow the steps in reverse order to reassemble your device.
Cancel: I did not complete this guide.
oldturkey03 is helping us fix the world! Want to contribute? Start translating ›
Special thanks to these translators:
100%
oldturkey03
Author
with 1 other contributor
VauWeh
Member since: 10/19/2015
160,518 Reputation
211 Guides authored
Badges:
41
+38 more badges